Product Name:
Human Troponin I Type 1, Slow Skeletal (TNNI1) ELISA Kit
Cat.#:
JL30282
Regulatory Status:
Alternative:
TNN1; Troponin I, slow-twitch isoform
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
46.87-3000pg/mL
Sensitivity:
18.62pg/mL
Specificity:
This kit recognizes Human TNNI1 in samples. No significant cross-reactivity or interference between Human TNNI1 and analogues was observed.
Sample Type:
serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:

Research Area:
Cardiovascular Biology
Product Datasheets
| TNNI1
Troponin I Type 1, Slow Skeletal (TNNI1) is a protein encoded by the TNNI1 gene.It is a tissue-specific subtype of troponin I, which in turn is a part of the troponin complex.The function of TnI is to control striated muscle contraction and relaxation. Troponin I interacts with all major regulatory proteins in the sarcomeric thin filaments of cardiac and skeletal muscles: troponin C, troponin T, tropomyosin and actin.When cytosolic Ca2+ is low, TnI binds the thin filament to block the myosin binding sites on actin.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (pg/mL) | 3000 | 1500 | 750 | 375 | 187.5 | 93.75 | 46.87 | 0 |
OD | 2.36 | 1.56 | 1.04 | 0.65 | 0.46 | 0.34 | 0.29 | 0.1 |
Corrected OD | 2.26 | 1.46 | 0.94 | 0.55 | 0.36 | 0.24 | 0.19 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human TNNI1 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 84-101 | 96 |
Plasma(n=8) | 92-105 | 102 |
Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human TNNI1 and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
Average (%) | 91 | 93 | 96 | |
1 : 4 | Range (%) | 89-102 | 87-108 | 105-115 |
Average (%) | 94 | 98 | 108 |






Size
Quantity
Price ($)
48T


420 / 420
96T


640 / 640