400-0066-400

Human Intercellular Adhesion Molecule 3 (ICAM-3) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human Intercellular Adhesion Molecule 3 (ICAM-3) ELISA Kit
Product Name:

Human Intercellular Adhesion Molecule 3 (ICAM-3) ELISA Kit

Cat.#:

JL29701

Regulatory Status:
Alternative:

CD50; CDW 50; CDw50; ICAM 3; ICAM-3; ICAM-R; Intercellular adhesion molecule 3

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.78-50ng/mL
Sensitivity:
0.42ng/mL
Specificity:
This kit recognizes Human ICAM-3 in samples. No significant cross-reactivity or interference between Human ICAM-3 and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates, cell lysates, cell culture supernatants and other biological fluids.
Assay Procedure:
Assay Procedure
Research Area:
Cell Biology
  • Human Intercellular Adhesion Molecule 3 (ICAM-3) ELISA Kit
  • Human Intercellular Adhesion Molecule 3 (ICAM-3) ELISA Kit
  • Human Intercellular Adhesion Molecule 3 (ICAM-3) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| ICAM-3

Intercellular Adhesion Molecule 3 (ICAM3) also known as CD5, is a protein encoded by the ICAM3 gene.The protein is constitutively expressed on the surface of leukocytes, which are also called white blood cells and are part of the immune system. ICAM3 mediates adhesion between cells by binding to specific integrin receptors. It plays an important role in the immune cell response through its facilitation of interactions between T cells and dendritic cells, which allows for T cell activation. ICAM3 also mediates the clearance of cells undergoing apoptosis by attracting and binding macrophages, a type of cell that breaks down infected or dying cells through a process known as phagocytosis, to apoptotic cells.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 50 25 12.5 6.25 3.12 1.56 0.78 0
OD 2.31 1.52 1.01 0.63 0.44 0.32 0.24 0.09
Corrected OD 2.22 1.43 0.92 0.54 0.35 0.23 0.15 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human ICAM-3 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 92-105 102
Cell Culture Supernates(n=8) 96-108 105





 

| Linearity

Samples were spiked with high concentrations of Human ICAM-3 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Cell Culture Supernates(n=4)
1 : 2 Range (%) 84-95 88-96 90-110
Average (%) 91 92 96
1 : 4 Range (%) 89-103 87-108 105-116
Average (%) 94 98 108







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
420 / 420
96T
1
640 / 640