400-0066-400

Human Carcinoembryonic Antigen (CEA) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human Carcinoembryonic Antigen (CEA) ELISA Kit
Product Name:

Human Carcinoembryonic Antigen (CEA) ELISA Kit

Cat.#:

JL19231

Regulatory Status:
Alternative:

CD66E; CD66; CEACAM5; Carcinoembryonic Antigen-related Cell Adhesion Molecule 5; Carcinoembryonic Antigen

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
19.53-1250pg/mL
Sensitivity:
7.35pg/mL
Specificity:
This kit recognizes Human CEA in samples. No significant cross-reactivity or interference between Human CEA and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Cancer
  • Human Carcinoembryonic Antigen (CEA) ELISA Kit
  • Human Carcinoembryonic Antigen (CEA) ELISA Kit
  • Human Carcinoembryonic Antigen (CEA) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| CEA

Carcinoembryonic antigen (CEA) describes a set of highly-related glycoproteins involved in cell adhesion. CEA is normally produced in gastrointestinal tissue during fetal development, but the production stops before birth. Consequently, CEA is usually present at very low levels in the blood of healthy adults (about 2–4 ng/mL). However, the serum levels are raised in some types of cancer, which means that it can be used as a tumor marker in clinical tests. Serum levels can also be elevated in heavy smokers.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (pg/mL) 1250 625 312.5 156.2 78.1 39.06 19.53 0
OD 2.05 1.12 0.57 0.35 0.25 0.2 0.18 0.08
Corrected OD 1.97 1.04 0.49 0.27 0.17 0.12 0.1 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human CEA spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 92-105 102
Cell Culture Supernates(n=8) 96-108 105





 

| Linearity

Samples were spiked with high concentrations of Human CEA and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Cell Culture Supernates(n=4)
1 : 2 Range (%) 84-95 88-96 90-110
Average (%) 91 93 95
1 : 4 Range (%) 89-103 87-108 105-115
Average (%) 94 98 108







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
336 / 336
96T
1
432 / 432
Top