Product Name:
Human Angiotensin II Receptor 2 (ATR-2) ELISA Kit
Cat.#:
JL15309
Regulatory Status:
Alternative:
AT2R; AT2-R; ATGR2; AT2; MRX88
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.15-10ng/mL
Sensitivity:
0.06ng/mL
Specificity:
This kit recognizes Human ATR-2 in samples. No significant cross-reactivity or interference between Human ATR-2 and analogues was observed.
Sample Type:
Tissue homogenates, cell lysates and other biological fluids
Assay Procedure:

Research Area:
Signal Transduction
Product Datasheets
| ATR-2
Angiotensin II receptor type 2, also known as the AT2 receptor is a protein that is encoded by the AGTR2 gene.Angiotensin II is a potent pressor hormone and a primary regulator of aldosterone secretion. It is an important effector controlling blood pressure and volume in the cardiovascular system. It acts through at least two types of receptors termed AT1 and AT2. AGTR2 belongs to a family 1 of G protein-coupled receptors. It is an integral membrane protein. It plays a role in the central nervous system and cardiovascular functions that are mediated by the renin–angiotensin system.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.62 | 0.31 | 0.15 | 0 |
OD | 2.28 | 1.85 | 1.23 | 0.8 | 0.53 | 0.39 | 0.3 | 0.08 |
Corrected OD | 2.2 | 1.77 | 1.15 | 0.72 | 0.45 | 0.31 | 0.22 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human ATR-2 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 84-101 | 96 |
Plasma(n=8) | 92-104 | 101 |
Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human ATR-2 and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
1 : 2 | Range (%) | 84-96 | 88-96 | 90-110 |
Average (%) | 92 | 93 | 96 | |
1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
Average (%) | 94 | 98 | 108 |






Size
Quantity
Price ($)
48T


360 / 360
96T