Product Name:
Human Complement Component 1, Q Receptor (C1qR1;CD93) ELISA Kit
Cat.#:
JL12252
Regulatory Status:
Alternative:
CDw93; CD93; C1qRP; C1q-R; MXRA4; Matrix-remodeling-associated protein 4; CD93 Antigen; C1q/MBL/SPA receptor; Complement component 1 q subcomponent receptor 1
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
15.62-1000pg/mL
Sensitivity:
6.34pg/mL
Specificity:
This kit recognizes Human C1qR1;CD93 in samples. No significant cross-reactivity or interference between Human C1qR1;CD93 and analogues was observed.
Sample Type:
serum, plasma and other biological fluids
Assay Procedure:

Research Area:
Signal Transduction
Product Datasheets
| C1qR1;CD93
CD93 (Cluster of Differentiation 93) is a protein that is encoded by the CD93 gene.CD93 is a C-type lectin transmembrane receptor which plays a role not only in cell–cell adhesion processes but also in host defense.CD93 belongs to the Group XIV C-Type lectin family,a group containing three other members, endosialin (CD248), CLEC14A and thrombomodulin, a well characterized anticoagulant. All of them contain a C-type lectin domain, a series of epidermal growth factor like domains, a highly glycosylated mucin-like domain, a unique transmembrane domain and a short cytoplasmic tail.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (pg/mL) | 1000 | 500 | 250 | 125 | 62.5 | 31.25 | 15.62 | 0 |
OD | 2.39 | 1.73 | 1.2 | 0.78 | 0.49 | 0.35 | 0.23 | 0.08 |
Corrected OD | 2.31 | 1.65 | 1.12 | 0.7 | 0.41 | 0.27 | 0.15 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human C1qR1;CD93 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 85-101 | 97 |
Plasma(n=8) | 92-105 | 102 |
| Linearity
Samples were spiked with high concentrations of Human C1qR1;CD93 and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | ||
1 : 2 | Range (%) | 84-95 | 88-96 |
Average (%) | 91 | 93 | |
1 : 4 | Range (%) | 88-103 | 87-107 |
Average (%) | 93 | 98 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460