Product Name:
Human Soluble CD27 Antigen (sCD27) ELISA Kit
Cat.#:
JL46904
Regulatory Status:
Alternative:
CD27 antigen; CD27L receptor; T-cell activation antigen CD27; T14; Tumor necrosis factor receptor superfamily member 7; TNFRSF7; CD27
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.156-10ng/mL
Sensitivity:
0.077ng/mL
Specificity:
This kit recognizes Human sCD27 in samples. No significant cross-reactivity or interference between Human sCD27 and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates
Assay Procedure:
Research Area:
Immunology
Product Datasheets
| sCD27
CD27 antigen is a member of the tumor necrosis factor receptor superfamily. The protein encoded by this gene is a member of the TNF receptor superfamily. It binds to its ligand CD70 and plays a key role in regulating B-cell activation and immunoglobulin synthesis. Upon binding to CD70, a signaling cascade leads to T-cell differentiation and clonal expansion. This cascade also leads to enhanced survival and memory of cytotoxic T cells and an increase in certain cytokines.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0.156 | 0 |
| OD | 2.44 | 1.44 | 0.94 | 0.61 | 0.35 | 0.23 | 0.16 | 0.08 |
| Corrected OD | 2.36 | 1.36 | 0.86 | 0.53 | 0.27 | 0.15 | 0.08 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human sCD27 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 90-115 | 98 |
| Plasma(n=8) | 82-99 | 93 |
| Tissue Homogenates(n=8) | 80-101 | 95 |
| Linearity
Samples were spiked with high concentrations of Human sCD27 and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Tissue Homogenates(n=4) | ||
| 1 : 2 | Range (%) | 100-116 | 84-101 | 83-112 |
| Average (%) | 107 | 95 | 92 | |
| 1 : 4 | Range (%) | 87-105 | 92-110 | 82-104 |
| Average (%) | 97 | 105 | 96 |
Size
Quantity
Price ($)
48T
1
420 / 420
96T
1
640 / 640


