Product Name:
Human MHC Class I Polypeptide-related Sequence B (MICB) ELISA Kit
Cat.#:
JL19585
Regulatory Status:
Alternative:
MHC class I polypeptide-related sequence B; MIC-B; PERB11.2
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
15.62-1000pg/mL
Sensitivity:
6.55pg/mL
Specificity:
This kit recognizes Human MICB in samples. No significant cross-reactivity or interference between Human MICB and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenate, cell lysate, cell culture supernatant and other biological fluids
Assay Procedure:
Research Area:
Immunology
Product Datasheets
| MICB
MHC class I chain-related genes MICA and MICB are transmembrane glycoproteins that can function as ligands for human NKG2D. These two proteins are highly related, sharing 85% amino acid identity, but are also polymorphic. Recognition of MICA or MICB by NKG2D leads to activation of NK cell cytolytic activity and/or cytokine production. MICA/B are expressed at minimal levels on normal cells but are frequently expressed on or shed from epithelial tumors, and can be induced by bacterial and viral infections. MICA and MICB recognition is involved in tumor surveillance, viral infection, and autoimmune diseases.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (pg/mL) | 1000 | 500 | 250 | 125 | 62.5 | 31.25 | 15.62 | 0 |
| OD | 2.64 | 1.92 | 1.19 | 0.73 | 0.45 | 0.29 | 0.21 | 0.08 |
| Corrected OD | 2.56 | 1.84 | 1.11 | 0.65 | 0.37 | 0.21 | 0.13 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human MICB spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 84-101 | 97 |
| Plasma(n=8) | 92-106 | 101 |
| Cell Culture Supernates(n=8) | 96-111 | 107 |
| Linearity
Samples were spiked with high concentrations of Human MICB and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 82-93 | 88-97 | 90-110 |
| Average (%) | 91 | 92 | 98 | |
| 1 : 4 | Range (%) | 89-102 | 87-109 | 105-115 |
| Average (%) | 94 | 99 | 108 |
Size
Quantity
Price ($)
48T
1
360 / 360
96T
1
640 / 640