Product Name:
Human Protein FAM3C (FAM3C) ELISA Kit
Cat.#:
JL10764
Regulatory Status:
Alternative:
FAM3C
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.15-10ng/mL
Sensitivity:
0.076ng/mL
Specificity:
This kit recognizes Human FAM3C in samples. No significant cross-reactivity or interference between Human FAM3C and analogues was observed.
Sample Type:
Tissue homogenate, cell culture supernatant and other biological fluids
Assay Procedure:
Research Area:
Cancer
Product Datasheets
| FAM3C
Sequence similarity family 3 member C, also known as FAM3C, is a protein encoded by the FAM3C gene. This gene is a member of the sequence similarity 3 (FAM3) family and encodes a secreted protein containing a GG domain. Altered expression of this protein has been noted in pancreatic cancer-derived cells. Alternative transcript splice variants, encoding the same protein, have been characterized. Its function and expression have also been investigated in the mammalian brain, suggesting that reduced FAM3C levels are associated with the onset of sporadic Alzheimer's disease (AD), highlighting FAM3C as a promising therapeutic target for Alzheimer's disease. Furthermore, FAM3C levels, along with saposin D, have been proposed as a biomarker for AD.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.62 | 0.31 | 0.15 | 0 |
| OD | 2.11 | 1.65 | 1.1 | 0.81 | 0.48 | 0.3 | 0.21 | 0.08 |
| Corrected OD | 2.03 | 1.57 | 1.02 | 0.73 | 0.4 | 0.22 | 0.13 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human FAM3C spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Tissue Homogenates(n=8) | 92-105 | 104 |
| Cell Lysates(n=8) | 96-107 | 105 |
| Linearity
Samples were spiked with high concentrations of Human FAM3C and diluted with Universal Diluent to produce samples with values within the range of the assay.| Tissue Homogenates(n=4) | Cell Lysates(n=4) | ||
| 1 : 2 | Range (%) | 88-96 | 90-110 |
| Average (%) | 94 | 96 | |
| 1 : 4 | Range (%) | 89-108 | 105-115 |
| Average (%) | 98 | 108 |
Size
Quantity
Price ($)
48T
1
320 / 320
96T
1
516 / 516