Product Name:
Human Soluble OX40L (sOX40L) ELISA Kit
Cat.#:
JL19586
Regulatory Status:
Alternative:
CD 134L;CD 252;CD134 ligand;CD134L;CD252;CD252 antigen;glycoprotein 34 kd;Glycoprotein Gp34;GP34;OX-40L;OX40 antigen ligand;OX40 ligand;OX40L;TAX transcriptionally-activated glycoprotein 1;TNFL4_HUMAN;Tnfsf4;Tumor necrosis factor (ligand) superfamily memb
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.156-10ng/mL
Sensitivity:
0.082ng/mL
Specificity:
This kit recognizes Human sOX40L in samples. No significant cross-reactivity or interference between Human sOX40L and analogues was observed.
Sample Type:
Tissue homogenates;cell lysates and other biological fluids
Assay Procedure:
Research Area:
Signal Transduction
Product Datasheets
| sOX40L
OX40L is the ligand for OX40 and is stably expressed on many antigen-presenting cells such as DC2s (a subtype of dendritic cells),macrophages, and activated B lymphocytes.The ligation of OX40-OX40L is a source of survival signal for T cells[6] and enables the development of memory T cells.Signaling through these two molecules also leads to polarization towards Th2 immune response even in an environment with low levels of IL-4 cytokine.OX40L is also present on the surface of many non-immune cells, for example, endothelial cells and smooth muscle cells.The surface expression of OX40L is induced by many pro-inflammatory mediators, such as TNF-α, e.g. produced by mast cells, IFN-γ and PGE2 (prostaglandin E2).OX40L has also been designated CD252 (cluster of differentiation 252).| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0.156 | 0 |
| OD | 2.52 | 1.96 | 1.38 | 0.97 | 0.55 | 0.31 | 0.19 | 0.08 |
| Corrected OD | 2.44 | 1.88 | 1.3 | 0.88 | 0.47 | 0.23 | 0.11 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human sOX40L spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Tissue Homogenates(n=8) | 92-105 | 102 |
| Cell Lysates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human sOX40L and diluted with Universal Diluent to produce samples with values within the range of the assay.| Tissue Homogenates(n=4) | Cell Lysates(n=4) | ||
| 1 : 2 | Range (%) | 88-100 | 90-110 |
| Average (%) | 93 | 96 | |
| 1 : 4 | Range (%) | 87-107 | 105-115 |
| Average (%) | 98 | 109 |
Size
Quantity
Price ($)
48T
1
360 / 360
96T
1
460 / 460