Product Name:
Human Breast And Kidney Expressed Chemokine (BRAK;CXCL14) ELISA Kit
Cat.#:
JL10980
Regulatory Status:
Alternative:
BRAK; SCYB14; BRAK; NJAC; Bolekine; Kec; MIP2-G; MIP2g; BMAC; KS1; Breast And Kidney Expressed Chemokine; Small Inducible Cytokine Subfamily B(Cys-X-Cys)Member 14
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.15-10ng/mL
Sensitivity:
0.06ng/mL
Specificity:
This kit recognizes Human BRAK;CXCL14 in samples. No significant cross-reactivity or interference between Human BRAK;CXCL14 and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:

Research Area:
Immunology
Product Datasheets
| BRAK;CXCL14
Chemokine (C-X-C motif) ligand 14 (CXCL14) is a small cytokine belonging to the CXC chemokine family that is also known as BRAK (for breast and kidney-expressed chemokine).Mature CXCL14 has many of the conserved features of the CXC chemokine subfamily but has some differences too, such as a shorter N-terminus and five extra amino acids in the region between its third and fourth cysteines.CXCL14 is constitutively expressed at high levels in many normal tissues, where its cellular source is thought to be fibroblasts.However, it is reduced or absent from most cancer cells.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.62 | 0.31 | 0.15 | 0 |
OD | 2.15 | 1.63 | 1.13 | 0.71 | 0.5 | 0.33 | 0.23 | 0.07 |
Corrected OD | 2.08 | 1.56 | 1.06 | 0.64 | 0.43 | 0.26 | 0.16 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human BRAK;CXCL14 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 84-103 | 98 |
Plasma(n=8) | 93-105 | 102 |
Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human BRAK;CXCL14 and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
1 : 2 | Range (%) | 84-95 | 88-94 | 90-110 |
Average (%) | 91 | 91 | 96 | |
1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
Average (%) | 94 | 98 | 108 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460