Product Name:
Human Pulmonary Activation Regulated Chemokine (PARC;CCL18) ELISA Kit
Cat.#:
JL12536
Regulatory Status:
Alternative:
CCL18; AMAC1; SCYA18; DCCK1; MIP-4; CKb7; Alternative Macrophage Activation Associated CC Chemokine 1; Chemokine C-C-Motif Ligand 18; Macrophage inflammatory protein 4
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.19-12.5ng/mL
Sensitivity:
0.08ng/mL
Specificity:
This kit recognizes Human PARC;CCL18 in samples. No significant cross-reactivity or interference between Human PARC;CCL18 and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:

Research Area:
Immunology
Product Datasheets
| PARC;CCL18
Chemokine (C-C motif) ligand 18 (CCL18) is a small cytokine belonging to the CC chemokine family. The functions of CCL18 have been well studied in laboratory settings, however the physiological effects of the molecule in living organisms have been difficult to characterize because there is no similar protein in rodents that can be studied.CCL18 is produced and secreted mainly by innate immune system, and has effects mainly on the adaptive immune system. It was previously known as Pulmonary and activation-regulated chemokine (PARC), dendritic cell (DC)-chemokine 1 (DC-CK1), alternative macrophage activation-associated CC chemokine-1 (AMAC-1), and macrophage inflammatory protein-4 (MIP-4).| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (ng/mL) | 12.5 | 6.25 | 3.12 | 1.56 | 0.78 | 0.39 | 0.19 | 0 |
OD | 2.35 | 1.55 | 1.03 | 0.64 | 0.45 | 0.33 | 0.24 | 0.09 |
Corrected OD | 2.26 | 1.46 | 0.94 | 0.55 | 0.36 | 0.24 | 0.15 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human PARC;CCL18 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 84-101 | 96 |
Plasma(n=8) | 92-105 | 102 |
Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human PARC;CCL18 and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
Average (%) | 91 | 93 | 96 | |
1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
Average (%) | 94 | 98 | 108 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460