Product Name:
Human Anoctamin 6 (ANO6) ELISA Kit
Cat.#:
JL17204
Regulatory Status:
Alternative:
TMEM16F; SCAN channel; Transmembrane Protein 16F; Small-conductance calcium-activated nonselective cation channel
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
7.8-500pg/mL
Sensitivity:
3.6pg/mL
Specificity:
This kit recognizes Human ANO6 in samples. No significant cross-reactivity or interference between Human ANO6 and analogues was observed.
Sample Type:
Tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Research Area:
Neuroscience
Product Datasheets
| ANO6
Anoctamin 6 is a protein that is encoded by the ANO6 gene.This protein is a multi-pass transmembrane protein that belongs to the anoctamin family. It is an essential component for the calcium-dependent exposure of phosphatidylserine on the cell surface. The scrambling of phospholipid occurs in various biological systems, such as when blood platelets are activated, they expose phosphatidylserine to trigger the clotting system. Mutations in this gene are associated with Scott syndrome. Alternatively spliced transcript variants encoding different isoforms have been found for this gene.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (pg/mL) | 500 | 250 | 125 | 62.5 | 31.25 | 15.62 | 7.8 | 0 |
| OD | 2.36 | 1.78 | 1.23 | 0.79 | 0.46 | 0.29 | 0.17 | 0.09 |
| Corrected OD | 2.27 | 1.69 | 1.14 | 0.7 | 0.37 | 0.2 | 0.08 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human ANO6 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Tissue Homogenates(n=8) | 90-105 | 102 |
| Cell Culture Supernates(n=8) | 96-108 | 104 |
| Linearity
Samples were spiked with high concentrations of Human ANO6 and diluted with Universal Diluent to produce samples with values within the range of the assay.| Tissue Homogenates(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 88-98 | 90-110 |
| Average (%) | 93 | 96 | |
| 1 : 4 | Range (%) | 87-108 | 105-115 |
| Average (%) | 98 | 109 |
Size
Quantity
Price ($)
48T
1
280 / 280
96T
1
460 / 460