Home > Sandwich ELISA Kits > Human Bcl2/Adenovirus E1B 19kDa Interacting Protein 3 (BNIP3) ELISA Kit
Product Name:
Human Bcl2/Adenovirus E1B 19kDa Interacting Protein 3 (BNIP3) ELISA Kit
Cat.#:
JL34153
Regulatory Status:
Alternative:
NIP3
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.156-10ng/mL
Sensitivity:
0.072ng/mL
Specificity:
This kit recognizes Human BNIP3 in samples. No significant cross-reactivity or interference between Human BNIP3 and analogues was observed.
Sample Type:
Tissue homogenates;cell lysates and other biological fluids
Assay Procedure:
Research Area:
Immunology
Product Datasheets
| BNIP3
BCL2/adenovirus E1B 19 kDa protein-interacting protein 3 is a protein found that is encoded by the BNIP3 gene. BNIP3 is a member of the apoptotic Bcl-2 protein family. It can induce cell death while also assisting with cell survival. Like many of the Bcl-2 family proteins, BNIP3 modulates the permeability state of the outer mitochondrial membrane by forming homo- and hetero-oligomers inside the membrane. Upregulation results in a decrease in mitochondrial potential, an increase in reactive oxygen species, mitochondrial swelling and fission, and an increase in mitochondrial turnover via autophagy.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0.156 | 0 |
| OD | 2.39 | 1.92 | 1.56 | 1.04 | 0.74 | 0.47 | 0.32 | 0.07 |
| Corrected OD | 2.32 | 1.85 | 1.49 | 0.97 | 0.67 | 0.4 | 0.25 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human BNIP3 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Tissue Homogenates(n=8) | 84-102 | 96 |
| Cell Lysates(n=8) | 92-105 | 102 |
| Linearity
Samples were spiked with high concentrations of Human BNIP3 and diluted with Universal Diluent to produce samples with values within the range of the assay.| Tissue Homogenates(n=4) | Cell Lysates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 88-96 |
| Average (%) | 91 | 93 | |
| 1 : 4 | Range (%) | 89-103 | 87-108 |
| Average (%) | 94 | 98 |
Size
Quantity
Price ($)
48T
1
360 / 360
96T
1
640 / 640