Detection Range:
1.56-100ng/mL
Sensitivity:
0.77ng/mL
Specificity:
This kit recognizes Human CD100 in samples. No significant cross-reactivity or interference between Human CD100 and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Neuroscience
  • Human Semaphorin 4D (CD100) ELISA Kit
  • Human Semaphorin 4D (CD100) ELISA Kit
  • Human Semaphorin 4D (CD100) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| CD100

Semaphorin-4D (SEMA4D) also known as Cluster of Differentiation 100 (CD100), is a protein of the semaphorin family that is encoded by the SEMA4D gene.Semaphorin 4D (Sema 4D) is an axon guidance molecule which is secreted by oligodendrocytes and induces growth cone collapse in the central nervous system. By binding plexin B1 receptor it functions as an R-Ras GTPase-activating protein (GAP) and repels axon growth cones in both the mature central nervous system.In the immune system, CD100 binds CD72 to activate B cells and dendritic cells, though much about this interaction is still under investigation.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 100 50 25 12.5 6.25 3.12 1.56 0
OD 2.51 1.96 1.24 0.72 0.46 0.3 0.22 0.09
Corrected OD 2.42 1.87 1.15 0.63 0.37 0.21 0.13 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human CD100 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 92-105 102
Tissue Homogenates(n=8) 96-108 105





 

| Linearity

Samples were spiked with high concentrations of Human CD100 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Tissue Homogenates(n=4)
1 : 2 Range (%) 84-95 88-96 89-110
Average (%) 91 93 96
1 : 4 Range (%) 89-103 87-108 105-115
Average (%) 94 98 109







 