Product Name:
Human CD177 Antigen (CD177) ELISA Kit
Cat.#:
JL52611
Regulatory Status:
Alternative:
CD177 antigen;CD177;HNA-2a;HNA2A;NB1;NB1 GP;PRV-1;PRV1;CD177 molecule
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.9-60ng/mL
Sensitivity:
0.4ng/mL
Specificity:
This kit recognizes Human CD177 in samples. No significant cross-reactivity or interference between Human CD177 and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Research Area:
Immunology
Product Datasheets
| CD177
CD177 antigen is a protein that is encoded by the CD177 gene. NB1, a glycosyl-phosphatidylinositol (GPI)-linked N-glycosylated cell surface glycoprotein, was first described in a case of neonatal alloimmune neutropenia.The protein can bind platelet endothelial cell adhesion molecule-1 and function in neutrophil transmigration. Mutations in this gene are associated with myeloproliferative diseases. Over-expression of this gene has been found in patients with polycythemia rubra vera.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 60 | 30 | 15 | 7.5 | 3.7 | 1.8 | 0.9 | 0 |
| OD | 2.17 | 1.74 | 1.17 | 0.78 | 0.47 | 0.32 | 0.23 | 0.08 |
| Corrected OD | 2.09 | 1.66 | 1.09 | 0.7 | 0.39 | 0.24 | 0.15 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human CD177 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 84-101 | 95 |
| Plasma(n=8) | 92-106 | 103 |
| Cell Culture Supernates(n=8) | 96-109 | 105 |
| Linearity
Samples were spiked with high concentrations of Human CD177 and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 88-95 | 90-110 |
| Average (%) | 91 | 93 | 96 | |
| 1 : 4 | Range (%) | 89-103 | 87-108 | 105-114 |
| Average (%) | 94 | 98 | 107 |