Product Name:
Human Cluster Of Differentiation 34 (CD34) ELISA Kit
Cat.#:
JL14300
Regulatory Status:
Alternative:
Hematopoietic progenitor cell antigen CD34
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.312-20ng/mL
Sensitivity:
0.16ng/mL
Specificity:
This kit recognizes Human CD34 in samples. No significant cross-reactivity or interference between Human CD34 and analogues was observed.
Sample Type:
tissue homogenates;cell lysates and other biological fluids
Assay Procedure:
Research Area:
Cancer
Product Datasheets
| CD34
CD34 is a transmembrane phosphoglycoprotein protein encoded by the CD34 gene.CD34 derives its name from the cluster of differentiation protocol that identifies cell surface antigens. CD34 was first described on hematopoietic stem cells independently by Civin et al. and Tindle et al. as a cell surface glycoprotein and functions as a cell-cell adhesion factor. It may also mediate the attachment of hematopoietic stem cells to bone marrow extracellular matrix or directly to stromal cells. Clinically, it is associated with the selection and enrichment of hematopoietic stem cells for bone marrow transplants.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 20 | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0 |
| OD | 2.31 | 1.29 | 0.72 | 0.45 | 0.31 | 0.22 | 0.18 | 0.08 |
| Corrected OD | 2.23 | 1.21 | 0.64 | 0.37 | 0.23 | 0.14 | 0.1 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human CD34 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Tissue Homogenates(n=8) | 84-101 | 97 |
| Cell Lysates(n=8) | 93-105 | 103 |
| Linearity
Samples were spiked with high concentrations of Human CD34 and diluted with Universal Diluent to produce samples with values within the range of the assay.| Tissue Homogenates(n=4) | Cell Lysates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 88-97 |
| Average (%) | 91 | 94 | |
| 1 : 4 | Range (%) | 89-103 | 87-108 |
| Average (%) | 94 | 98 |
Size
Quantity
Price ($)
48T
1
280 / 280
96T
1
460 / 460