Product Name:
Human Target Of Myb Protein 1 (TOM1) ELISA Kit
Cat.#:
JL15883
Regulatory Status:
Alternative:
TOM1; target of myb1 membrane trafficking protein; IMD85
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.312-20ng/mL
Sensitivity:
0.17ng/mL
Specificity:
This kit recognizes Human TOM1 in samples. No significant cross-reactivity or interference between Human TOM1 and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Research Area:
Cell Biology
Product Datasheets
| TOM1
Target of Myb protein 1 is a protein that is encoded by the TOM1 gene.The specific function of this gene has not yet been determined, yet it may involve the translocation of growth factor receptor complexes to the lysosome for degradation. This gene is localized to 22q13.1, with HMOX1 and MCM5 distally and HMG2L1 proximally positioned.Adapter protein that plays a role in the intracellular membrane trafficking of ubiquitinated proteins, thereby participating in autophagy, ubiquitination-dependent signaling and receptor recycling pathways. Acts as a MYO6/Myosin VI adapter protein that targets MYO6 to endocytic structures. Together with MYO6, required for autophagosomal delivery of endocytic cargo, the maturation of autophagosomes and their fusion with lysosomes.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 20 | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0 |
| OD | 2.45 | 1.88 | 1.46 | 1.13 | 0.76 | 0.49 | 0.38 | 0.08 |
| Corrected OD | 2.37 | 1.8 | 1.38 | 1.05 | 0.68 | 0.41 | 0.3 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human TOM1 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 84-101 | 96 |
| Plasma(n=8) | 92-106 | 103 |
| Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human TOM1 and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 89-96 | 89-110 |
| Average (%) | 91 | 94 | 96 | |
| 1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
| Average (%) | 94 | 98 | 108 |
Size
Quantity
Price ($)
48T
1
360 / 360
96T
1
460 / 460