400-0066-400

Human NADPH Oxidase (NADPH-OX) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human NADPH Oxidase (NADPH-OX) ELISA Kit
Product Name:

Human NADPH Oxidase (NADPH-OX) ELISA Kit

Cat.#:

JL14361

Regulatory Status:
Alternative:

NADPH oxidase

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.156-10ng/mL
Sensitivity:
0.076ng/mL
Specificity:
This kit recognizes Human NADPH-OX in samples. No significant cross-reactivity or interference between Human NADPH-OX and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Metabolism
  • Human NADPH Oxidase (NADPH-OX) ELISA Kit
  • Human NADPH Oxidase (NADPH-OX) ELISA Kit
  • Human NADPH Oxidase (NADPH-OX) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| NADPH-OX

NADPH oxidase (nicotinamide adenine dinucleotide phosphate oxidase) is a membrane-bound enzyme complex that faces the extracellular space. It can be found in the plasma membrane as well as in the membranes of phagosomes used by neutrophil white blood cells to engulf microorganisms.NADPH oxidase catalyzes the production of a superoxide free radical by transferring one electron to oxygen from NADPH.In mammals, NADPH oxidase is found in two types: one in white blood cells (neutrophilic) and the other in vascular cells, differing in biochemical structure and functions.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 10 5 2.5 1.25 0.625 0.312 0.156 0
OD 2.32 1.7 1.19 0.72 0.46 0.32 0.22 0.07
Corrected OD 2.25 1.63 1.12 0.65 0.39 0.25 0.15 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human NADPH-OX spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 92-104 101
Cell Culture Supernates(n=8) 96-108 105





 

| Linearity

Samples were spiked with high concentrations of Human NADPH-OX and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Cell Culture Supernates(n=4)
1 : 2 Range (%) 84-95 88-96 90-110
Average (%) 91 93 96
1 : 4 Range (%) 89-103 87-108 105-114
Average (%) 94 98 107







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
360 / 360
96T
1
460 / 460