400-0066-400

Human O-Linked-N-Acetylglucosamine Transferase (OGT) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human O-Linked-N-Acetylglucosamine Transferase (OGT) ELISA Kit
Product Name:

Human O-Linked-N-Acetylglucosamine Transferase (OGT) ELISA Kit

Cat.#:

JL10094

Regulatory Status:
Alternative:

HRNT1; O-GLCNAC; UDP-N-acetylglucosamine--peptide N-acetylglucosaminyltransferase 110 kDa subunit; O-GlcNAc transferase subunit p110

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
1.56-100ng/mL
Sensitivity:
0.8ng/mL
Specificity:
This kit recognizes Human OGT in samples. No significant cross-reactivity or interference between Human OGT and analogues was observed.
Sample Type:
Tissue homogenates;cell lysates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Signal Transduction
  • Human O-Linked-N-Acetylglucosamine Transferase (OGT) ELISA Kit
  • Human O-Linked-N-Acetylglucosamine Transferase (OGT) ELISA Kit
  • Human O-Linked-N-Acetylglucosamine Transferase (OGT) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| OGT

Protein O-GlcNAc transferase also known as OGT or O-linked N-acetylglucosaminyltransferase is an enzyme that is encoded by the OGT gene. OGT catalyzes the addition of the O-GlcNAc post-translational modification to proteins. OGT catalyzes the addition of a single N-acetylglucosamine through an O-glycosidic linkage to serine or threonine and an S-glycosidic linkage to cysteine residues of nucleocytoplasmic proteins. Since both phosphorylation and O-GlcNAcylation compete for similar serine or threonine residues, the two processes may compete for sites, or they may alter the substrate specificity of nearby sites by steric or electrostatic effects.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 100 50 25 12.5 6.25 3.12 1.56 0
OD 2.22 1.56 0.92 0.63 0.42 0.25 0.18 0.08
Corrected OD 2.14 1.48 0.84 0.55 0.34 0.17 0.1 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human OGT spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Tissue Homogenates(n=8) 84-103 98
Cell Lysates(n=8) 96-108 105





 

| Linearity

Samples were spiked with high concentrations of Human OGT and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Tissue Homogenates(n=4) Cell Lysates(n=4)
1 : 2 Range (%) 88-96 90-110
Average (%) 93 96
1 : 4 Range (%) 87-108 105-115
Average (%) 98 108







 