Product Name:
Human Procollagen Ⅲ Propeptide (PⅢP) ELISA Kit
Cat.#:
JL14261
Regulatory Status:
Alternative:
"procollagen 3 propeptide;P3P; procollagen III propeptide;PIIIP"
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.93-60ng/mL
Sensitivity:
0.469ng/mL
Specificity:
This kit recognizes Human PⅢP in samples. No significant cross-reactivity or interference between Human PⅢP and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Research Area:
Immunology
Product Datasheets
| PⅢP
Procollagen Type III N-Terminal Peptide (PIIIP) is a crucial biomarker for assessing liver fibrosis, with its serum levels reflecting hepatic collagen metabolism and liver function. The intact PIIIP is primarily cleared through receptor-mediated endocytosis by hepatic sinusoidal endothelial cells, while smaller fragments are eliminated via renal excretion. Elevated serum PIIIP concentrations indicate active fibrogenesis and impaired hepatic clearance capacity, correlating significantly with the degree of hepatocyte necrosis, portal inflammation, and progressive fibrotic changes in chronic liver diseases.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 60 | 30 | 15 | 7.5 | 3.75 | 1.87 | 0.93 | 0 |
| OD | 2.02 | 1.22 | 0.75 | 0.47 | 0.3 | 0.22 | 0.18 | 0.08 |
| Corrected OD | 1.94 | 1.14 | 0.67 | 0.39 | 0.22 | 0.14 | 0.1 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human PⅢP spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 84-101 | 96 |
| Plasma(n=8) | 92-105 | 102 |
| Cell Culture Supernates(n=8) | 96-107 | 104 |
| Linearity
Samples were spiked with high concentrations of Human PⅢP and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 88-97 | 90-110 |
| Average (%) | 91 | 93 | 96 | |
| 1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
| Average (%) | 94 | 98 | 108 |
Size
Quantity
Price ($)
48T
1
360 / 360
96T
1
460 / 460