Product Name:
Human Tripartite Motif-Containing Protein 29 (TRIM29) ELISA Kit
Cat.#:
JL27699
Regulatory Status:
Alternative:
ATDC; tripartite motif containing 29
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.156-10ng/mL
Sensitivity:
0.081ng/mL
Specificity:
This kit recognizes Human TRIM29 in samples. No significant cross-reactivity or interference between Human TRIM29 and analogues was observed.
Sample Type:
Tissue homogenates;cell lysates and other biological fluids
Assay Procedure:
Research Area:
Developmental Biology
Product Datasheets
| TRIM29
Tripartite motif-containing protein 29 is a protein that is encoded by the TRIM29 gene.The protein belongs to the TRIM protein family. It has multiple zinc finger motifs and a leucine zipper motif. It has been proposed to form homo- or heterodimers which are involved in nucleic acid binding. Thus, it may act as a transcriptional regulatory factor involved in carcinogenesis and/or differentiation. It may also function in the suppression of radiosensitivity since it is associated with ataxia–telangiectasia phenotype.TRIM29 has been shown to interact with TRIM23 and GCC1.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0.156 | 0 |
| OD | 2.22 | 1.56 | 0.92 | 0.63 | 0.42 | 0.25 | 0.18 | 0.08 |
| Corrected OD | 2.14 | 1.48 | 0.84 | 0.55 | 0.34 | 0.17 | 0.1 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human TRIM29 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Tissue Homogenates(n=8) | 84-101 | 96 |
| Cell Lysates(n=8) | 96-108 | 102 |
| Linearity
Samples were spiked with high concentrations of Human TRIM29 and diluted with Universal Diluent to produce samples with values within the range of the assay.| Tissue Homogenates(n=4) | Cell Lysates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 90-110 |
| Average (%) | 91 | 96 | |
| 1 : 4 | Range (%) | 89-104 | 105-115 |
| Average (%) | 94 | 108 |
Size
Quantity
Price ($)
48T
1
360 / 360
96T
1
460 / 460