Product Name:
Human Acetyl Coenzyme A Carboxylase Alpha (ACACa) ELISA Kit
Cat.#:
JL41013
Regulatory Status:
Alternative:
ACAC; ACC1; ACCA; ACAC; ACC2; ACCB; ACACB; ACACA; Acetyl CoA Carboxylase; Biotin carboxylase
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
3.12-200ng/mL
Sensitivity:
1.6ng/mL
Specificity:
This kit recognizes Human ACACA in samples. No significant cross-reactivity or interference between Human ACACA and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Research Area:
Metabolism
Product Datasheets
| ACACA
Acetyl-CoA carboxylase (ACC) is a biotin-dependent enzyme that catalyzes the irreversible carboxylation of acetyl-CoA to produce malonyl-CoA through its two catalytic activities, biotin carboxylase (BC) and carboxyltransferase (CT). ACC is a multi-subunit enzyme in most prokaryotes and in the chloroplasts of most plants and algae, whereas it is a large, multi-domain enzyme in the cytoplasm of most eukaryotes. The most important function of ACC is to provide the malonyl-CoA substrate for the biosynthesis of fatty acids.The activity of ACC can be controlled at the transcriptional level as well as by small molecule modulators and covalent modification.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 200 | 100 | 50 | 25 | 12.5 | 6.25 | 3.12 | 0 |
| OD | 2.52 | 1.96 | 1.38 | 0.97 | 0.55 | 0.31 | 0.19 | 0.08 |
| Corrected OD | 2.44 | 1.88 | 1.3 | 0.88 | 0.47 | 0.23 | 0.11 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human ACACA spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 84-101 | 96 |
| Plasma(n=8) | 92-105 | 102 |
| Linearity
Samples were spiked with high concentrations of Human ACACA and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 88-96 |
| Average (%) | 91 | 93 | |
| 1 : 4 | Range (%) | 89-103 | 87-108 |
| Average (%) | 94 | 98 |
Size
Quantity
Price ($)
48T
1
360 / 360
96T
1
460 / 460