Product Name:
Human Bisphosphoglycerate Mutase (BPGM) ELISA Kit
Cat.#:
JL53042
Regulatory Status:
Alternative:
2;3-Bisphosphoglycerate Mutase; 2;3-bisphosphoglycerate mutase; erythrocyte; 2;3-bisphosphoglycerate synthase; BPG-dependent PGAM
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.31-20ng/mL
Sensitivity:
0.18ng/mL
Specificity:
This kit recognizes Human BPGM in samples. No significant cross-reactivity or interference between Human BPGM and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenatesand other biological fluids
Assay Procedure:
Research Area:
Metabolism
Product Datasheets
| BPGM
Bisphosphoglycerate mutase (BPGM) is an enzyme expressed in erythrocytes and placental cells.It is responsible for the catalytic synthesis of 2,3-Bisphosphoglycerate (2,3-BPG) from 1,3-bisphosphoglycerate. BPGM also has a mutase and a phosphatase function.1,3-BPG is formed as an intermediate in glycolysis. BPGM then takes this and converts it to 2,3-BPG, which serves an important function in oxygen transport. 2,3-BPG binds with high affinity to Hemoglobin, causing a conformational change that results in the release of oxygen. Local tissues can then pick up the free oxygen.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 20 | 10 | 5 | 2.5 | 1.25 | 0.62 | 0.31 | 0 |
| OD | 2.52 | 1.96 | 1.38 | 0.97 | 0.55 | 0.31 | 0.19 | 0.08 |
| Corrected OD | 2.44 | 1.88 | 1.3 | 0.88 | 0.47 | 0.23 | 0.11 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human BPGM spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Tissue Homogenates(n=8) | 92-105 | 102 |
| Cell Lysates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human BPGM and diluted with Universal Diluent to produce samples with values within the range of the assay.| Tissue Homogenates(n=4) | Cell Lysates(n=4) | ||
| 1 : 2 | Range (%) | 88-96 | 90-110 |
| Average (%) | 93 | 96 | |
| 1 : 4 | Range (%) | 87-108 | 105-115 |
| Average (%) | 98 | 108 |
Size
Quantity
Price ($)
48T
1
396 / 396
96T
1
516 / 516