Product Name:
Human Secreted Alkaline Phos-phatase (SEAP) ELISA Kit
Cat.#:
JL46216
Regulatory Status:
Alternative:
secreted alkaline phos-phatase
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
3.12-200ng/mL
Sensitivity:
1.54ng/mL
Specificity:
This kit recognizes Human SEAP in samples. No significant cross-reactivity or interference between Human SEAP and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Research Area:
Cell Biology
Product Datasheets
| SEAP
The enzyme alkaline phosphatase (ALP, alkaline phenyl phosphatase, also abbreviated PhoA) is a phosphatase with the physiological role of dephosphorylating compounds. The enzyme is found across a multitude of organisms, prokaryotes and eukaryotes alike, with the same general function, but in different structural forms suitable to the environment they function in. Alkaline phosphatase is found in the periplasmic space of E. coli bacteria. This enzyme is heat stable and has its maximum activity at high pH.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 200 | 100 | 50 | 25 | 12.5 | 6.25 | 3.12 | 0 |
| OD | 2.14 | 1.63 | 1.16 | 0.78 | 0.57 | 0.36 | 0.24 | 0.07 |
| Corrected OD | 2.07 | 1.56 | 1.09 | 0.71 | 0.5 | 0.29 | 0.17 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human SEAP spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 84-101 | 96 |
| Plasma(n=8) | 92-105 | 102 |
| Cell Culture Supernates(n=8) | 96-109 | 105 |
| Linearity
Samples were spiked with high concentrations of Human SEAP and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
| Average (%) | 91 | 93 | 96 | |
| 1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
| Average (%) | 95 | 98 | 108 |