Product Name:
Human Cystatin 4 (CST4) ELISA Kit
Cat.#:
JL13767
Regulatory Status:
Alternative:
Cystatin S; Salivary acidic protein 1; Cystatin-SA-III
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.156-10ng/mL
Sensitivity:
0.073ng/mL
Specificity:
This kit recognizes Human CST4 in samples. No significant cross-reactivity or interference between Human CST4 and analogues was observed.
Sample Type:
Serum;plasma;saliva;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Research Area:
Immunology
Product Datasheets
| CST4
Cystatin-S is a protein that is encoded by the CST4 gene.The cystatin superfamily encompasses proteins that contain multiple cystatin-like sequences. Some of the members are active cysteine protease inhibitors, while others have lost or perhaps never acquired this inhibitory activity. There are three inhibitory families in the superfamily, including the type 1 cystatins (stefins), type 2 cystatins and the kininogens. The type 2 cystatin proteins are a class of cysteine proteinase inhibitors found in a variety of human fluids and secretions. The cystatin locus on chromosome 20 contains the majority of the type 2 cystatin genes and pseudogenes.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0.156 | 0 |
| OD | 2.37 | 1.58 | 1.01 | 0.65 | 0.43 | 0.31 | 0.22 | 0.09 |
| Corrected OD | 2.28 | 1.49 | 0.92 | 0.56 | 0.34 | 0.22 | 0.13 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human CST4 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 84-101 | 96 |
| Plasma(n=8) | 93-105 | 103 |
| Cell Culture Supernates(n=8) | 97-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human CST4 and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
| Average (%) | 91 | 93 | 96 | |
| 1 : 4 | Range (%) | 89-103 | 87-108 | 104-115 |
| Average (%) | 94 | 98 | 107 |
Size
Quantity
Price ($)
48T
1
360 / 360
96T
1