Product Name:
Human Solubility Leukocyte Antigen G (sHLA-G) ELISA Kit
Cat.#:
JL19595
Regulatory Status:
Alternative:
sHLA-G
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
1.25-80ng/mL
Sensitivity:
0.5ng/mL
Specificity:
This kit recognizes Human sHLA-G in samples. No significant cross-reactivity or interference between Human sHLA-G and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Research Area:
Immunology
Product Datasheets
| sHLA-G
HLA-G histocompatibility antigen, class I, G, also known as human leukocyte antigen G (HLA-G), is a protein that is encoded by the HLA-G gene.HLA-G belongs to the HLA nonclassical class I heavy chain paralogues. Classical HLA I proteins are found on all nucleated cells and express peptides in their peptide binding groove. They can express "self" peptides when the cell is healthy as well as foreign peptides when the cell is infected by a parasite or cancer. HLA-G is a nonclassical protein and serves a different function from classical HLA class I molecules, but it still expresses a nine amino acid peptide in its peptide binding groove.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 80 | 40 | 20 | 10 | 5 | 2.5 | 1.25 | 0 |
| OD | 2.3 | 1.65 | 1.06 | 0.56 | 0.29 | 0.17 | 0.11 | 0.05 |
| Corrected OD | 2.25 | 1.6 | 1.01 | 0.51 | 0.24 | 0.12 | 0.06 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human sHLA-G spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 84-101 | 96 |
| Plasma(n=8) | 93-105 | 102 |
| Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human sHLA-G and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 88-96 | 90-111 |
| Average (%) | 91 | 93 | 96 | |
| 1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
| Average (%) | 94 | 98 | 108 |
Size
Quantity
Price ($)
48T
1
360 / 360
96T
1
640 / 640