Product Name:
Human Vesicular Acetylcholine Transporter (VAChT) ELISA Kit
Cat.#:
JL17970
Regulatory Status:
Alternative:
SLC18A3; Solute Carrier Family 18 Member 3;Vesicular Acetylcholine
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.312-20ng/mL
Sensitivity:
0.15ng/mL
Specificity:
This kit recognizes Human VAChT in samples. No significant cross-reactivity or interference between Human VAChT and analogues was observed.
Sample Type:
Tissue homogenates;cell lysates and other biological fluids
Assay Procedure:
Research Area:
Signal Transduction
Product Datasheets
| VAChT
The Vesicular acetylcholine transporter (VAChT) is a neurotransmitter transporter which is responsible for loading acetylcholine (ACh) into secretory organelles in neurons making acetylcholine available for secretion. It is encoded by Solute carrier family 18, member 3 (SLC18A3) gene, located within the first intron of the choline acetyltransferase gene. VAChT is able to transport ACh into vesicles by relying on an exchange between protons (H+) that were previously pumped into the vesicle diffusing out, thus acting as an antiporter. ACh molecules are then carried into the vesicle by the action of exiting protons. Acetylcholine transport utilizes a proton gradient established by a vacuolar ATPase.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 20 | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0 |
| OD | 2.14 | 1.63 | 1.16 | 0.78 | 0.57 | 0.36 | 0.24 | 0.07 |
| Corrected OD | 2.07 | 1.56 | 1.09 | 0.71 | 0.5 | 0.29 | 0.17 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human VAChT spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Tissue Homogenates(n=8) | 83-101 | 96 |
| Cell Lysates(n=8) | 92-105 | 101 |
| Linearity
Samples were spiked with high concentrations of Human VAChT and diluted with Universal Diluent to produce samples with values within the range of the assay.| Tissue Homogenates(n=4) | Cell Lysates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 88-99 |
| Average (%) | 91 | 93 | |
| 1 : 4 | Range (%) | 89-103 | 87-108 |
| Average (%) | 95 | 98 |
Size
Quantity
Price ($)
48T
1
360 / 360
96T
1
460 / 460