Product Name:
Human Vesicular Monoamine Transporter 2 (VMAT2) ELISA Kit
Cat.#:
JL17968
Regulatory Status:
Alternative:
SLC18A2; SVMT; SVAT; Solute Carrier Family 18 Member 2;Vesicular Monoamine; Monoamine transporter; Synaptic vesicular amine transporter
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.156-10ng/mL
Sensitivity:
0.081ng/mL
Specificity:
This kit recognizes Human VMAT2 in samples. No significant cross-reactivity or interference between Human VMAT2 and analogues was observed.
Sample Type:
tissue homogenates;cell lysates and other biological fluids
Assay Procedure:
Research Area:
Signal Transduction
Product Datasheets
| VMAT2
The solute carrier family 18 member 2 (SLC18A2) also known as vesicular monoamine transporter 2 (VMAT2) is a protein that is encoded by the SLC18A2 gene. SLC18A2 is an integral membrane protein that transports monoamines—particularly neurotransmitters such as dopamine, norepinephrine, serotonin, and histamine—from cellular cytosol into synaptic vesicles. In nigrostriatal pathway and mesolimbic pathway dopamine-releasing neurons, SLC18A2 function is also necessary for the vesicular release of the neurotransmitter GABA.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0.156 | 0 |
| OD | 2.21 | 1.82 | 1.51 | 1.08 | 0.79 | 0.5 | 0.35 | 0.09 |
| Corrected OD | 2.12 | 1.73 | 1.42 | 0.99 | 0.7 | 0.41 | 0.26 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human VMAT2 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Tissue Homogenates(n=8) | 91-105 | 102 |
| Cell Lysates(n=8) | 96-108 | 104 |
| Linearity
Samples were spiked with high concentrations of Human VMAT2 and diluted with Universal Diluent to produce samples with values within the range of the assay.| Tissue Homogenates(n=4) | Cell Lysates(n=4) | ||
| 1 : 2 | Range (%) | 84-96 | 90-110 |
| Average (%) | 93 | 96 | |
| 1 : 4 | Range (%) | 87-108 | 105-115 |
| Average (%) | 98 | 109 |
Size
Quantity
Price ($)
48T
1
360 / 360
96T
1
460 / 460