Product Name:
Human Very Low Density LipoProtein Cholesterol (VLDL-C) ELISA Kit
Cat.#:
JL46536
Regulatory Status:
Alternative:
Very low density lipoprotein cholesterol
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.156-10ng/mL
Sensitivity:
0.073ng/mL
Specificity:
This kit recognizes Human VLDL-C in samples. No significant cross-reactivity or interference between Human VLDL-C and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Research Area:
Cardiovascular Biology
Product Datasheets
| VLDL-C
Very low-density lipoprotein cholesterol (VLDL-C) is primarily synthesized in the liver and plays a crucial role in transporting endogenously produced triglycerides (TGs). Its degradation is influenced by various factors, including diet, enterhepatic circulation, capillary endothelial function, and hormones such as adrenaline. VLDL (very low-density lipoprotein) is a lipoprotein particle produced in the liver, carrying triglycerides and cholesterol. VLDL-C specifically refers to the cholesterol content within VLDL particles, serving as an important biomarker for lipid metabolism assessment.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0.156 | 0 |
| OD | 2.28 | 1.82 | 1.23 | 0.8 | 0.53 | 0.36 | 0.23 | 0.08 |
| Corrected OD | 2.2 | 1.74 | 1.15 | 0.72 | 0.45 | 0.28 | 0.15 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human VLDL-C spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 84-102 | 97 |
| Plasma(n=8) | 92-105 | 102 |
| Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human VLDL-C and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 88-95 | 90-110 |
| Average (%) | 91 | 92 | 95 | |
| 1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
| Average (%) | 94 | 98 | 108 |
Size
Quantity
Price ($)
48T
1
360 / 360
96T
1
460 / 460


