Product Name:
Human Activated Coagulation Factor VIIa (FVIIa) ELISA Kit
Cat.#:
JL17268
Regulatory Status:
Alternative:
Activated Coagulation Factor VIIa
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
15.6-1000ng/mL
Sensitivity:
7.7ng/mL
Specificity:
This kit recognizes Human FVIIa in samples. No significant cross-reactivity or interference between Human FVIIa and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Research Area:
Cardiovascular Biology
Product Datasheets
| FVIIa
Coagulation factor VII ,(formerly known as proconvertin)is a protein involved in coagulation and, is encoded by gene F7. It is an enzyme of the serine protease class. Once bound to tissue factor released from damaged tissues, it is converted to factor VIIa (or blood-coagulation factor VIIa, activated blood coagulation factor VII), which in turn activates factor IX and factor X.FVII bound to TF, FVII is activated to FVIIa by different proteases, among which are thrombin (factor IIa), factor Xa, IXa, XIIa, and the FVIIa-TF complex itself. The complex of factor VIIa with TF catalyzes the conversion of factor IX and factor X into the active proteases, factor IXa and factor Xa, respectively.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 1000 | 500 | 250 | 125 | 62.5 | 31.2 | 15.6 | 0 |
| OD | 2.24 | 1.63 | 1.01 | 0.55 | 0.44 | 0.31 | 0.25 | 0.09 |
| Corrected OD | 2.15 | 1.54 | 0.92 | 0.46 | 0.35 | 0.22 | 0.16 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human FVIIa spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 84-101 | 96 |
| Plasma(n=8) | 92-106 | 103 |
| Cell Culture Supernates(n=8) | 96-107 | 105 |
| Linearity
Samples were spiked with high concentrations of Human FVIIa and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
| Average (%) | 91 | 93 | 96 | |
| 1 : 4 | Range (%) | 89-103 | 87-108 | 105-114 |
| Average (%) | 94 | 98 | 107 |
Size
Quantity
Price ($)
48T
1
360 / 360
96T
1
460 / 460