400-0066-400

Human Ecto-NOX Disulfide-thiol Exchanger 2 (ENOX2) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human Ecto-NOX Disulfide-thiol Exchanger 2 (ENOX2) ELISA Kit
Product Name:

Human Ecto-NOX Disulfide-thiol Exchanger 2 (ENOX2) ELISA Kit

Cat.#:

JL15986

Regulatory Status:
Alternative:

APK1;APK1 antigen;COVA1;Cytosolic ovarian carcinoma antigen 1;Ecto NOX disulfide thiol exchanger 2;ENOX 2;ENOX2;ENOX2_HUMAN;OTTHUMP00000024021;OTTHUMP00000024022;Protein disulfide-thiol oxidoreductase;tNOX;Tumor associated hydroquinone oxidase;Tumor-assoc

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
31.2-2000pg/mL
Sensitivity:
15.8pg/mL
Specificity:
This kit recognizes Human ENOX2 in samples. No significant cross-reactivity or interference between Human ENOX2 and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Neuroscience
  • Human Ecto-NOX Disulfide-thiol Exchanger 2 (ENOX2) ELISA Kit
  • Human Ecto-NOX Disulfide-thiol Exchanger 2 (ENOX2) ELISA Kit
  • Human Ecto-NOX Disulfide-thiol Exchanger 2 (ENOX2) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| ENOX2

ENOX2 is a gene located on the long arm of the X chromosome. The gene encodes the protein Ecto-NOX disulfide-thiol exchanger 2, a member of the NOX family of NADPH oxidases.Ecto-NOX disulfide-thiol exchanger 2 is a growth-related cell surface protein. It was identified because it reacts with the monoclonal antibody K1 in cells, such as the ovarian carcinoma line OVCAR-3, also expressing the CAKI surface glycoprotein. The encoded protein has two enzymatic activities: catalysis of hydroquinone or NADH oxidation, and protein disulfide interchange. The two activities alternate with a period length of about 24 minutes. The encoded protein also displays prion-like properties.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (pg/mL) 2000 1000 500 250 125 62.5 31.2 0
OD 2.36 1.7 1.26 0.87 0.6 0.4 0.28 0.09
Corrected OD 2.27 1.61 1.17 0.78 0.51 0.31 0.19 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human ENOX2 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 92-106 103
Cell Culture Supernates(n=8) 96-108 105





 

| Linearity

Samples were spiked with high concentrations of Human ENOX2 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Cell Culture Supernates(n=4)
1 : 2 Range (%) 84-95 88-96 90-110
Average (%) 91 93 96
1 : 4 Range (%) 89-103 87-107 105-115
Average (%) 94 97 108







 
Close