400-0066-400

Human Interleukin 1 (IL-1) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human Interleukin 1 (IL-1) ELISA Kit
Product Name:

Human Interleukin 1 (IL-1) ELISA Kit

Cat.#:

JL19245

Regulatory Status:
Alternative:

Interleukin 1

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
31.2-2000pg/mL
Sensitivity:
15.2pg/mL
Specificity:
This kit recognizes Human IL-1 in samples. No significant cross-reactivity or interference between Human IL-1 and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Immunology
  • Human Interleukin 1 (IL-1) ELISA Kit
  • Human Interleukin 1 (IL-1) ELISA Kit
  • Human Interleukin 1 (IL-1) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| IL-1

Interleukin-1 (IL-1) is a key mediator of inflammation and immunity.IL-1 is a well-characterized proinflammatory cytokine that is involved in host defense and autoimmune diseases. IL-1 can promote activation of T cells, including Th1 cells, Th2 cells and Th17 cells, and B cells, suggesting that IL-1 may contribute to the development of various types of T-cell-mediated diseases.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (pg/mL) 2000 1000 500 250 125 62.5 31.2 0
OD 2.36 1.49 0.95 0.54 0.35 0.26 0.21 0.09
Corrected OD 2.27 1.4 0.86 0.45 0.26 0.17 0.12 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human IL-1 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 92-105 102
Cell Culture Supernates(n=8) 96-108 105





 

| Linearity

Samples were spiked with high concentrations of Human IL-1 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Cell Culture Supernates(n=4)
1 : 2 Range (%) 84-95 88-97 89-110
Average (%) 91 93 96
1 : 4 Range (%) 89-103 87-108 105-115
Average (%) 94 98 108







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
280 / 280
96T
1
360 / 360
Top