Product Name:
Human Interleukin 17 Receptor A (IL-17RA) ELISA Kit
Cat.#:
JL53592
Regulatory Status:
Alternative:
IL17RA
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
78.12-5000pg/mL
Sensitivity:
39.05pg/mL
Specificity:
This kit recognizes Human IL-17RA in samples. No significant cross-reactivity or interference between Human IL-17RA and analogues was observed.
Sample Type:
Tissue homogenates;cell lysates and other biological fluids
Assay Procedure:
Research Area:
Neuroscience
Product Datasheets
| IL-17RA
Interleukin 17 receptor A, also known as IL17RA and CDw217 (cluster of differentiation w217).Interleukin 17A (IL17A)is a proinflammatory cytokine secreted by activated T-lymphocytes. It is a potent inducer of the maturation of CD34-positive hematopoietic precursors into neutrophils. The protein encoded by this gene (interleukin 17A receptor; IL17RA) is a ubiquitous type I membrane glycoprotein that binds with low affinity to interleukin 17A. Interleukin 17A and its receptor play a pathogenic role in many inflammatory and autoimmune diseases such as rheumatoid arthritis. Like other cytokine receptors, this receptor likely has a multimeric structure.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (pg/mL) | 5000 | 2500 | 1250 | 625 | 312.5 | 156.25 | 78.12 | 0 |
| OD | 2.22 | 1.56 | 0.92 | 0.63 | 0.42 | 0.25 | 0.18 | 0.08 |
| Corrected OD | 2.14 | 1.48 | 0.84 | 0.55 | 0.34 | 0.17 | 0.1 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human IL-17RA spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Tissue Homogenates(n=8) | 84-101 | 95 |
| Cell Lysates(n=8) | 96-108 | 104 |
| Linearity
Samples were spiked with high concentrations of Human IL-17RA and diluted with Universal Diluent to produce samples with values within the range of the assay.| Tissue Homogenates(n=4) | Cell Lysates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 90-110 |
| Average (%) | 91 | 96 | |
| 1 : 4 | Range (%) | 89-103 | 105-114 |
| Average (%) | 94 | 107 |
Size
Quantity
Price ($)
48T
1
396 / 396
96T
1
516 / 516