Product Name:
Human Interleukin 38 (IL-38) ELISA Kit
Cat.#:
JL19286
Regulatory Status:
Alternative:
IL1F10; IL38; FKSG75; IL-1HY2; IL-1F10; FIL1-Theta; Interleukin-38; Interleukin-1 Receptor Antagonist FKSG75; Interleukin 1 Family; Member 10
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
7.8-500pg/mL
Sensitivity:
3.4pg/mL
Specificity:
This kit recognizes Human IL-38 in samples. No significant cross-reactivity or interference between Human IL-38 and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Research Area:
Immunology
Product Datasheets
| IL-38
Interleukin-1 family member 10 is a protein that is encoded by the IL1F10 gene.The protein encoded by this gene is a member of the interleukin 1 cytokine family. This gene and eight other interleukin 1 family genes form a cytokine gene cluster on chromosome 2. This cytokine is thought to participate in a network of interleukin 1 family members to regulate adapted and innate immune responses. Two alternatively spliced transcript variants encoding the same protein have been reported.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (pg/mL) | 500 | 250 | 125 | 62.5 | 31.2 | 15.6 | 7.8 | 0 |
| OD | 2.36 | 1.56 | 1.04 | 0.65 | 0.46 | 0.34 | 0.29 | 0.1 |
| Corrected OD | 2.26 | 1.46 | 0.94 | 0.55 | 0.36 | 0.24 | 0.19 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human IL-38 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 84-101 | 96 |
| Plasma(n=8) | 92-105 | 102 |
| Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human IL-38 and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 85-95 | 88-96 | 90-110 |
| Average (%) | 90 | 93 | 96 | |
| 1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
| Average (%) | 94 | 98 | 108 |