400-0066-400

Human Leukocyte Associated Immunoglobulin Like Receptor 2 (LAIR2;CD306) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human Leukocyte Associated Immunoglobulin Like Receptor 2 (LAIR2;CD306) ELISA Kit
Product Name:

Human Leukocyte Associated Immunoglobulin Like Receptor 2 (LAIR2;CD306) ELISA Kit

Cat.#:

JL32429

Regulatory Status:
Alternative:

CD306

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
15.6-1000pg/mL
Sensitivity:
7.6pg/mL
Specificity:
This kit recognizes Human LAIR2;CD306 in samples. No significant cross-reactivity or interference between Human LAIR2;CD306 and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Immunology
  • Human Leukocyte Associated Immunoglobulin Like Receptor 2 (LAIR2;CD306) ELISA Kit
  • Human Leukocyte Associated Immunoglobulin Like Receptor 2 (LAIR2;CD306) ELISA Kit
  • Human Leukocyte Associated Immunoglobulin Like Receptor 2 (LAIR2;CD306) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| LAIR2;CD306

Leukocyte-associated immunoglobulin-like receptor 2 is a protein that is encoded by the LAIR2 gene.The protein encoded by this gene is a member of the immunoglobulin superfamily. It was identified by its similarity to LAIR1, an inhibitory receptor present on mononuclear leukocytes. This gene maps to a region of 19q13.4, termed the leukocyte receptor cluster, which contains 29 genes in the immunoglobulin superfamily, including LAIR1. The function of this protein is unknown, although it is thought to be secreted and may help modulate mucosal tolerance. Two transcript variants encoding different isoforms have been found for this gene.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (pg/mL) 1000 500 250 125 62.5 31.2 15.6 0
OD 2.38 1.7 1.12 0.72 0.44 0.32 0.23 0.08
Corrected OD 2.3 1.62 1.04 0.64 0.36 0.24 0.15 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human LAIR2;CD306 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 92-105 101
Tissue Homogenates(n=8) 96-108 105





 

| Linearity

Samples were spiked with high concentrations of Human LAIR2;CD306 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Tissue Homogenates(n=4)
1 : 2 Range (%) 84-95 88-97 90-110
Average (%) 91 93 96
1 : 4 Range (%) 89-103 87-108 105-114
Average (%) 94 98 108







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
420 / 420
96T
1
640 / 640
Top