Product Name:
Human Type Ⅱ Iodothyronine Deiodinase (DIO2) ELISA Kit
Cat.#:
JL10563
Regulatory Status:
Alternative:
5DII; D2; SelY; TXDI2; Thyroxine Deiodinase;Type II; Type-II 5'-deiodinase;Deiodinase; Iodothyronine; Type II
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.156-10ng/mL
Sensitivity:
0.083ng/mL
Specificity:
This kit recognizes Human DIO2 in samples. No significant cross-reactivity or interference between Human DIO2 and analogues was observed.
Sample Type:
tissue homogenates;cell lysates and other biological fluids
Assay Procedure:
Research Area:
Metabolism
Product Datasheets
| DIO2
Type II iodothyronine deiodinase (iodothyronine 5'-deiodinase, iodothyronine 5'-monodeiodinase) is an enzyme that is encoded by the DIO2 gene.The protein encoded by this gene belongs to the iodothyronine deiodinase family. It activates thyroid hormone by converting the prohormone thyroxine (T4) by outer ring deiodination (ORD) to bioactive 3,3',5-triiodothyronine (T3). It is highly expressed in the thyroid, and may contribute significantly to the relative increase in thyroidal T3 production in patients with Graves' disease and thyroid adenomas. This protein contains selenocysteine (Sec) residues encoded by the UGA codon, which normally signals translation termination.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0.156 | 0 |
| OD | 2.22 | 1.56 | 0.92 | 0.63 | 0.42 | 0.25 | 0.18 | 0.08 |
| Corrected OD | 2.14 | 1.48 | 0.84 | 0.55 | 0.34 | 0.17 | 0.1 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human DIO2 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Tissue Homogenates(n=8) | 84-101 | 96 |
| Cell Lysates(n=8) | 92-105 | 102 |
| Linearity
Samples were spiked with high concentrations of Human DIO2 and diluted with Universal Diluent to produce samples with values within the range of the assay.| Tissue Homogenates(n=4) | Cell Lysates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 83-96 |
| Average (%) | 91 | 93 | |
| 1 : 4 | Range (%) | 89-103 | 87-108 |
| Average (%) | 92 | 98 |
Size
Quantity
Price ($)
48T
1
360 / 360
96T
1
460 / 460