400-0066-400

Human Phospholipase A2, LipoProtein Associated (LpPLA2) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human Phospholipase A2, LipoProtein Associated (LpPLA2) ELISA Kit
Product Name:

Human Phospholipase A2, LipoProtein Associated (LpPLA2) ELISA Kit

Cat.#:

JL14636

Regulatory Status:
Alternative:

PLA2G7; PAF-AH; PAFAH; Lp-PLA2; LDL-PLA2; Platelet Activating Factor Acetylhydrolase;Plasma; Phospholipase A2;Group VII; LDL-associated phospholipase A2; Phospholipase A2; Lipoprotein Associated

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.625-40ng/mL
Sensitivity:
0.34ng/mL
Specificity:
This kit recognizes Human LpPLA2 in samples. No significant cross-reactivity or interference between Human LpPLA2 and analogues was observed.
Sample Type:
Serum;plasma and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Metabolism
  • Human Phospholipase A2, LipoProtein Associated (LpPLA2) ELISA Kit
  • Human Phospholipase A2, LipoProtein Associated (LpPLA2) ELISA Kit
  • Human Phospholipase A2, LipoProtein Associated (LpPLA2) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| LpPLA2

Lipoprotein-associated phospholipase A2 (Lp-PLA2) also known as platelet-activating factor acetylhydrolase (PAF-AH) is a phospholipase A2 enzyme that in humans is encoded by the PLA2G7 gene. Lp-PLA2 is a 45-kDa protein of 441 amino acids. Lp-PLA2 is platelet-activating factor (PAF) acetylhydrolase , a secreted enzyme that catalyzes the degradation of PAF to inactive products by hydrolysis of the acetyl group at the sn-2 position, producing the biologically inactive products LYSO-PAF and acetate.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 40 20 10 5 2.5 1.25 0.625 0
OD 2.36 1.78 1.23 0.79 0.46 0.29 0.17 0.09
Corrected OD 2.27 1.69 1.14 0.7 0.37 0.2 0.08 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human LpPLA2 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 92-105 102





 

| Linearity

Samples were spiked with high concentrations of Human LpPLA2 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4)
1 : 2 Range (%) 84-95 88-96
Average (%) 91 93
1 : 4 Range (%) 89-103 87-108
Average (%) 94 98







 