Product Name:
Human Apurinic/apyrimidinic Endonuclease 1 (APE1) ELISA Kit
Cat.#:
JL19859
Regulatory Status:
Alternative:
Apurinic/apyrimidinic endonuclease 1
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.156-10ng/mL
Sensitivity:
0.073ng/mL
Specificity:
This kit recognizes Human APE1 in samples. No significant cross-reactivity or interference between Human APE1 and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Research Area:
Cell Biology
Product Datasheets
| APE1
DNA-(apurinic or apyrimidinic site) lyase is an enzyme that is encoded by the APEX1 gene.Apurinic/apyrimidinic (AP) sites (also called "abasic sites") occur frequently in DNA molecules by spontaneous hydrolysis, by DNA damaging agents or by DNA glycosylases that remove specific abnormal bases. AP sites are pre-mutagenic lesions that can prevent normal DNA replication. All cells, from simple prokaryotes to humans, have evolved systems to identify and repair such sites. Class II AP endonucleases cleave the phosphodiester backbone 5' to the AP site, thereby initiating a process known as base excision repair (BER). The APEX gene (alternatively named APE1, HAP1, APEN) encodes the major AP endonuclease in human cells.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0.156 | 0 |
| OD | 2.49 | 1.62 | 0.96 | 0.53 | 0.33 | 0.24 | 0.2 | 0.08 |
| Corrected OD | 2.41 | 1.54 | 0.88 | 0.45 | 0.25 | 0.16 | 0.12 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human APE1 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 84-101 | 96 |
| Plasma(n=8) | 92-105 | 102 |
| Cell Culture Supernates(n=8) | 96-107 | 104 |
| Linearity
Samples were spiked with high concentrations of Human APE1 and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
| Average (%) | 91 | 93 | 96 | |
| 1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
| Average (%) | 94 | 98 | 108 |
Size
Quantity
Price ($)
48T
1
280 / 280
96T
1
460 / 460