400-0066-400

Human Annexin A11 (ANXA11) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human Annexin A11 (ANXA11) ELISA Kit
Product Name:

Human Annexin A11 (ANXA11) ELISA Kit

Cat.#:

JL54465

Regulatory Status:
Alternative:

ANX-A11; ANX11; CAP50; 56 kDa autoantigen; Calcyclin-associated annexin 50

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.156-10ng/mL
Sensitivity:
0.07ng/mL
Specificity:
This kit recognizes Human ANXA11 in samples. No significant cross-reactivity or interference between Human ANXA11 and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Immunology
  • Human Annexin A11 (ANXA11) ELISA Kit
  • Human Annexin A11 (ANXA11) ELISA Kit
  • Human Annexin A11 (ANXA11) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| ANXA11

Annexin A11 is a protein that is encoded by the ANXA11 gene.This protein is a member of the annexin family, a group of calcium-dependent phospholipid-binding proteins. Annexins have unique N-terminal domains and conserved C-terminal domains, which contain the calcium-dependent phospholipid-binding sites. It is a 56-kD antigen recognized by sera from patients with various autoimmune diseases. ANXA11 has been shown to interact with PDCD6 and ALG2.It is shown that over-expression of the ANXA11 is involved in apoptotic alterations in schizophrenia and contribute to pathomechanisms of this disorder.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 10 5 2.5 1.25 0.625 0.312 0.156 0
OD 2.52 1.96 1.38 0.97 0.55 0.31 0.19 0.08
Corrected OD 2.44 1.88 1.3 0.89 0.47 0.23 0.11 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human ANXA11 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Tissue Homogenates(n=8) 84-101 96
Cell Lysates(n=8) 92-105 102





 

| Linearity

Samples were spiked with high concentrations of Human ANXA11 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Tissue Homogenates(n=4) Cell Lysates(n=4)
1 : 2 Range (%) 84-95 85-96
Average (%) 91 93
1 : 4 Range (%) 89-103 87-108
Average (%) 96 98







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
320 / 320
96T
1
516 / 516
Top