400-0066-400

Human Complement Factor I (CFI) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human Complement Factor I (CFI) ELISA Kit
Product Name:

Human Complement Factor I (CFI) ELISA Kit

Cat.#:

JL14533

Regulatory Status:
Alternative:

CF-I; C3b-INA; FI; IF; KAF; Factor I; Konglutinogen-Activating Factor; C3b-Inactivator; C3B/C4B inactivator

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.156-10ng/mL
Sensitivity:
0.074ng/mL
Specificity:
This kit recognizes Human CFI in samples. No significant cross-reactivity or interference between Human CFI and analogues was observed.
Sample Type:
Serum;plasma and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Immunology
  • Human Complement Factor I (CFI) ELISA Kit
  • Human Complement Factor I (CFI) ELISA Kit
  • Human Complement Factor I (CFI) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| CFI

Complement factor I, also known as C3b/C4b inactivator, is a protein that is encoded by the CFI gene. Complement factor I (factor I) is a protein of the complement system, first isolated in 1966 in guinea pig serum,that regulates complement activation by cleaving cell-bound or fluid phase C3b and C4b.It is a soluble glycoprotein that circulates in human blood at an average concentration of 35 μg/mL.Dysregulated factor I activity has clinical implications. Loss of function mutations in the Complement Factor I gene lead to low levels of factor I which results in increased complement activity.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 10 5 2.5 1.25 0.625 0.312 0.156 0
OD 2.22 1.56 0.92 0.63 0.42 0.25 0.18 0.08
Corrected OD 2.14 1.48 0.84 0.55 0.34 0.17 0.1 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human CFI spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 92-105 102





 

| Linearity

Samples were spiked with high concentrations of Human CFI and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4)
1 : 2 Range (%) 84-95 88-96
Average (%) 91 93
1 : 4 Range (%) 89-103 87-108
Average (%) 94 98







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
320 / 320
96T
1
576 / 576
Top