Product Name:
Human Glutathione S Transferase Omega 1 (GSTo1) ELISA Kit
Cat.#:
JL54484
Regulatory Status:
Alternative:
"GSTO-1;GSTO1;GSTTLP28;Glutathione S-transferase omega 1-1 (GSTO 1-1) Glutathione-dependent dehydroascorbate reductase; Monomethylarsonic acid reductase (MMA(V) reductase) ; S-(Phenacyl)glutathione reductase (SPG-R)"
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.156-10ng/mL
Sensitivity:
0.076ng/mL
Specificity:
This kit recognizes Human GSTo1 in samples. No significant cross-reactivity or interference between Human GSTo1 and analogues was observed.
Sample Type:
Tissue homogenates;cell lysates and other biological fluids
Assay Procedure:
Research Area:
Neuroscience
Product Datasheets
| GSTo1
Glutathione S-transferase omega-1 is an enzyme that is encoded by the GSTO1 gene.This gene encodes a member of the theta class glutathione S-transferase-like (GSTTL) protein family.The protein is an omega class glutathione S-transferase (GST) with glutathione-dependent thiol transferase and dehydroascorbate reductase activities. GSTs are involved in the metabolism of xenobiotics and carcinogens.It acts as a homodimer and is found in the cytoplasm. Three transcript variants encoding different isoforms have been found for this gene.This protein has dehydroascorbate reductase activity and may function in the glutathione-ascorbate cycle as part of antioxidant metabolism.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0.156 | 0 |
| OD | 2.11 | 1.26 | 0.8 | 0.5 | 0.33 | 0.24 | 0.19 | 0.08 |
| Corrected OD | 2.03 | 1.18 | 0.72 | 0.42 | 0.25 | 0.16 | 0.11 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human GSTo1 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Tissue Homogenates(n=8) | 88-102 | 96 |
| Cell Lysates(n=8) | 94-107 | 104 |
| Linearity
Samples were spiked with high concentrations of Human GSTo1 and diluted with Universal Diluent to produce samples with values within the range of the assay.| Tissue Homogenates(n=4) | Cell Lysates(n=4) | ||
| 1 : 2 | Range (%) | 82-93 | 88-96 |
| Average (%) | 91 | 93 | |
| 1 : 4 | Range (%) | 89-103 | 87-110 |
| Average (%) | 94 | 99 |
Size
Quantity
Price ($)
48T
1
396 / 396
96T
1
516 / 516