Home > Sandwich ELISA Kits > Human Transcription Factor Vincristine-associated Solitary Receptor Gamma t (RORγt) ELISA Kit
Product Name:
Human Transcription Factor Vincristine-associated Solitary Receptor Gamma t (RORγt) ELISA Kit
Cat.#:
JL20088
Regulatory Status:
Alternative:
Transcription factor vincristine-associated solitary receptor gamma t
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
78-5000pg/mL
Sensitivity:
39.8pg/mL
Specificity:
This kit recognizes Human RORγt in samples. No significant cross-reactivity or interference between Human RORγt and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Research Area:
Neuroscience
Product Datasheets
| RORγt
RORγt (also known as RORγ2) – produced from an mRNA identical to that of RORγ, except that the two 5'-most exons are replaced by an alternative exon, located downstream in the gene. This causes a different, shorter N-terminus.RORγt, is expressed in various immune cells. Of those, the most prominent examples are immature CD4+/CD8+ thymocytes, T helper 17 (Th17) cells and in type 3 innate lymphoid cells (ILC3). Mice lacking RORγt are devoid of lymph nodes and Peyer's patches due to the lack of Lymphoid tissue inducer cells (LTi), a subpopulation of ILC3s and important drivers of lymphoid organogenesis.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (pg/mL) | 5000 | 2500 | 1250 | 625 | 312 | 156 | 78 | 0 |
| OD | 2.22 | 1.56 | 0.92 | 0.63 | 0.42 | 0.25 | 0.18 | 0.08 |
| Corrected OD | 2.14 | 1.48 | 0.84 | 0.55 | 0.34 | 0.17 | 0.1 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human RORγt spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 84-101 | 94 |
| Plasma(n=8) | 92-106 | 104 |
| Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human RORγt and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 88-95 | 90-110 |
| Average (%) | 91 | 93 | 96 | |
| 1 : 4 | Range (%) | 89-103 | 87-108 | 105-114 |
| Average (%) | 94 | 98 | 107 |
Size
Quantity
Price ($)
48T
1
360 / 360
96T
1
460 / 460