400-0066-400

Human Sodium-chloride Symporter (NCCT) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human Sodium-chloride Symporter (NCCT) ELISA Kit
Product Name:

Human Sodium-chloride Symporter (NCCT) ELISA Kit

Cat.#:

JL18018

Regulatory Status:
Alternative:

SLC12A3; TSC; NCC; Solute Carrier Family 12 Member 3;Sodium/Chloride Transporters; Thiazide-sensitive sodium-chloride cotransporter; Na-Cl symporter;Na-Cl Cotransporter

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.312-20ng/mL
Sensitivity:
0.153ng/mL
Specificity:
This kit recognizes Human NCCT in samples. No significant cross-reactivity or interference between Human NCCT and analogues was observed.
Sample Type:
Tissue homogenates;cell lysates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Signal Transduction
  • Human Sodium-chloride Symporter (NCCT) ELISA Kit
  • Human Sodium-chloride Symporter (NCCT) ELISA Kit
  • Human Sodium-chloride Symporter (NCCT) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| NCCT

The sodium-chloride symporter (also known as Na+-Cl− cotransporter, NCC or NCCT, or as the thiazide-sensitive Na+-Cl− cotransporter or TSC) is a cotransporter in the kidney which has the function of reabsorbing sodium and chloride ions from the tubular fluid into the cells of the distal convoluted tubule of the nephron. It is a member of the SLC12 cotransporter family of electroneutral cation-coupled chloride cotransporters. A loss of NCC function causes Gitelman syndrome, an autosomic recessive disease characterized by salt wasting and low blood pressure, hypokalemic metabolic alkalosis, hypomagnesemia and hypocalciuria.Over a hundred different mutations in the NCC gene have been identified.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 20 10 5 2.5 1.25 0.625 0.312 0
OD 2.44 1.91 1.37 0.84 0.51 0.34 0.26 0.07
Corrected OD 2.37 1.84 1.3 0.77 0.44 0.27 0.19 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human NCCT spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Tissue Homogenates(n=8) 84-102 96
Cell Lysates(n=8) 92-105 100





 

| Linearity

Samples were spiked with high concentrations of Human NCCT and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Tissue Homogenates(n=4) Cell Lysates(n=4)
1 : 2 Range (%) 82-95 88-96
Average (%) 91 93
1 : 4 Range (%) 89-103 87-108
Average (%) 94 100







 