Product Name:
Human H (+)/Sialic Acid Cotransporter (AST) ELISA Kit
Cat.#:
JL18005
Regulatory Status:
Alternative:
AST;SLC17A5; SD; ISSD; NSD; ;SIASD; SLD; Solute Carrier Family 17 Member 5; Sialic Acid Storage Disease; Vesicular H(+)/Aspartate-glutamate cotransporter;Anion/Sugar Transporter ;H(+)/nitrate cotransporter and H(+)/sialic acid cotransporter
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.312-20ng/mL
Sensitivity:
0.16ng/mL
Specificity:
This kit recognizes Human AST in samples. No significant cross-reactivity or interference between Human AST and analogues was observed.
Sample Type:
Tissue homogenates;cell lysates and other biological fluids
Assay Procedure:
Research Area:
Signal Transduction
Product Datasheets
| AST
Sialin, also known as H(+)/nitrate cotransporter and H(+)/sialic acid cotransporter, is a protein which is encoded by the SLC17A5 gene.A deficiency of this protein causes Salla disease and Infantile Sialic Acid Storage Disease (ISSD).The gene for HP59 contains, entirely within its coding region, the Sialin Gene SLC17A5. Member 5, also known as SLC17A5 or sialin is a lysosomal membrane sialic acid transport protein which in humans is encoded by the SLC17A5 gene on Chromosome 6.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 20 | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0 |
| OD | 2.36 | 1.56 | 1.04 | 0.65 | 0.46 | 0.34 | 0.29 | 0.1 |
| Corrected OD | 2.26 | 1.46 | 0.94 | 0.55 | 0.36 | 0.24 | 0.19 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human AST spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Tissue Homogenates(n=8) | 90-105 | 102 |
| Cell Lysates(n=8) | 96-108 | 104 |
| Linearity
Samples were spiked with high concentrations of Human AST and diluted with Universal Diluent to produce samples with values within the range of the assay.| Tissue Homogenates(n=4) | Cell Lysates(n=4) | ||
| 1 : 2 | Range (%) | 86-96 | 90-110 |
| Average (%) | 93 | 96 | |
| 1 : 4 | Range (%) | 87-108 | 105-115 |
| Average (%) | 98 | 109 |
Size
Quantity
Price ($)
48T
1
280 / 280
96T
1
460 / 460