Product Name:
Human Myeloid-derived Growth Factor (MYDGF) ELISA Kit
Cat.#:
JL47072
Regulatory Status:
Alternative:
C19orf10
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
31.25-2000pg/mL
Sensitivity:
15.2pg/mL
Specificity:
This kit recognizes Human MYDGF in samples. No significant cross-reactivity or interference between Human MYDGF and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;and other biological fluids
Assay Procedure:
Research Area:
Cardiovascular Biology
Product Datasheets
| MYDGF
Myeloid-derived growth factor(MYDGF) is a paracrine protein produced by bone marrow-derived monocytes and macrophages. It has protective effects on the cardiovascular system, such as repairing heart tissue after myocardial infarction, enhancing cardiomyocyte proliferation, improving cardiac regeneration after myocardial injury, regulating proliferation and survival of endothelial cells, reducing endothelial cell damage, resisting pressure overload-induced heart failure, as well as protecting against atherosclerosis. Furthermore, regarding the metabolic diseases, MYDGF has effects of improving type 2 diabetes mellitus, relieving non-alcoholic fatty liver disease, alleviating glomerular diseases, and resisting osteoporosis.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (pg/mL) | 2000 | 1000 | 500 | 250 | 125 | 62.5 | 31.25 | 0 |
| OD | 2.22 | 1.56 | 0.92 | 0.63 | 0.42 | 0.25 | 0.18 | 0.08 |
| Corrected OD | 2.14 | 1.48 | 0.84 | 0.55 | 0.34 | 0.17 | 0.1 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human MYDGF spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 84-101 | 96 |
| Plasma(n=8) | 92-105 | 102 |
| Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human MYDGF and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
| Average (%) | 91 | 93 | 96 | |
| 1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
| Average (%) | 94 | 98 | 108 |
Size
Quantity
Price ($)
48T
1
580 / 580
96T
1
700 / 700