Product Name:
Human NADPH Oxidase 2 (NOX2) ELISA Kit
Cat.#:
JL18618
Regulatory Status:
Alternative:
CGD; GP91PHOX; NOX2; Neutrophil cytochrome b91; Cytochrome b558 beta; Heme-binding membrane glycoprotein gp91phox; Superoxide-generating NADPH oxidase heavy chain;NOX2
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.156-10ng/mL
Sensitivity:
0.075ng/mL
Specificity:
This kit recognizes Human NOX2 in samples. No significant cross-reactivity or interference between Human NOX2 and analogues was observed.
Sample Type:
Tissue homogenates;cell lysates and other biological fluids
Assay Procedure:
Research Area:
Metabolism
Product Datasheets
| NOX2
NADPH oxidase 2 (Nox2), also known as cytochrome b(558) subunit beta or Cytochrome b-245 heavy chain, is a protein that is encoded by the NOX2 gene (also called CYBB gene). The protein is a superoxide generating enzyme which forms reactive oxygen species (ROS).The CYBB gene encode cytochrome b-245, beta chain. This protein is subunit of a group of proteins that forms an enzyme complex called NADPH oxidase, which plays an essential role in the immune system. Within this complex, the cytochrome b-245, beta chain has an alpha chain partner (produced from the CYBA gene). Both alpha and beta chains are required for either to function and the NADPH oxidase complex requires both chains in order to be functional.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0.156 | 0 |
| OD | 2.18 | 1.57 | 1.03 | 0.62 | 0.42 | 0.32 | 0.26 | 0.1 |
| Corrected OD | 2.08 | 1.47 | 0.93 | 0.52 | 0.32 | 0.22 | 0.16 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human NOX2 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Tissue Homogenates(n=8) | 83-101 | 95 |
| Cell Lysates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human NOX2 and diluted with Universal Diluent to produce samples with values within the range of the assay.| Tissue Homogenates(n=4) | Cell Lysates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 90-110 |
| Average (%) | 91 | 96 | |
| 1 : 4 | Range (%) | 89-103 | 105-115 |
| Average (%) | 94 | 109 |
Size
Quantity
Price ($)
48T
1
360 / 360
96T
1
460 / 460