Product Name:
Human Cluster Of Differentiation 74 (CD74) ELISA Kit
Cat.#:
JL47476
Regulatory Status:
Alternative:
MHCDG; HLA-DG; HLADG; DHLAG; Ia-GAMMA; HLA class II histocompatibility antigen gamma chain; Ia antigen-associated invariant chain; HLA-DR antigens-associated invariant chain
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
46.87-3000pg/mL
Sensitivity:
23.5pg/mL
Specificity:
This kit recognizes Human CD74 in samples. No significant cross-reactivity or interference between Human CD74 and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates, cell lysates, cell culture supernatants and other biological fluids
Assay Procedure:
Research Area:
Immunology
Product Datasheets
| CD74
HLA class II histocompatibility antigen gamma chain also known as HLA-DR antigens-associated invariant chain or CD74 (Cluster of Differentiation 74), is a protein that in humans is encoded by the CD74 gene.The invariant chain (Abbreviated Ii) is a polypeptide which plays a critical role in antigen presentation. It is involved in the formation and transport of MHC class II peptide complexes for the generation of CD4+ T cell responses.The cell surface form of the invariant chain is known as CD74. CD74 is a cell surface receptor for the cytokine macrophage migration inhibitory factor (MIF).| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (pg/mL) | 3000 | 1500 | 750 | 375 | 187.5 | 93.75 | 46.87 | 0 |
| OD | 2.36 | 1.78 | 1.23 | 0.79 | 0.46 | 0.29 | 0.17 | 0.09 |
| Corrected OD | 2.27 | 1.69 | 1.14 | 0.7 | 0.37 | 0.2 | 0.08 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human CD74 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 84-101 | 96 |
| Plasma(n=8) | 92-105 | 102 |
| Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human CD74 and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
| Average (%) | 91 | 93 | 96 | |
| 1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
| Average (%) | 94 | 98 | 108 |
Size
Quantity
Price ($)
48T
1
360 / 360
96T
1
460 / 460