Product Name:
Human Stromal Cell Derived Factor 1 (SDF-1a;CXCL12) ELISA Kit
Cat.#:
JL34680
Regulatory Status:
Alternative:
SDF-1a;CXCL12
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.15-10ng/mL
Sensitivity:
0.077ng/mL
Specificity:
This kit recognizes Human SDF-1a;CXCL12 in samples. No significant cross-reactivity or interference between Human SDF-1a;CXCL12 and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:

Research Area:
Cancer
Product Datasheets
| SDF-1a;CXCL12
This assay employs the sandwich enzyme immunoassay technique. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Human SDF-1a;CXCL12. Add Sample, Standard, and Streptavidin-HRP by turn, with incubation and washing. TMB Substrate is added for color development, and TMB will appear blue in color catalyzed by HRP and to a final yellow color in reaction to acid. The intensity of the color is positive to the Human SDF-1a;CXCL12 in the sample. The optical density (OD) is measured spectrophotometrically at a wavelength of 450nm. You can calculate the concentration of Human SDF-1a;CXCL12 in the samples by comparing the OD of the samples to the standard curve.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.62 | 0.31 | 0.15 | 0 |
OD | 2.48 | 1.65 | 1.07 | 0.71 | 0.45 | 0.28 | 0.19 | 0.09 |
Corrected OD | 2.39 | 1.56 | 0.98 | 0.62 | 0.36 | 0.19 | 0.1 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human SDF-1a;CXCL12 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 84-101 | 96 |
Plasma(n=8) | 92-105 | 102 |
Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human SDF-1a;CXCL12 and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
1 : 2 | Range (%) | 84-95 | 88-95 | 90-110 |
Average (%) | 91 | 92 | 96 | |
1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
Average (%) | 94 | 98 | 108 |






Size
Quantity
Price ($)
48T


400 / 400
96T


560 / 560