400-0066-400

Human Syndecan 3 (SDC3) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human Syndecan 3 (SDC3) ELISA Kit
Product Name:

Human Syndecan 3 (SDC3) ELISA Kit

Cat.#:

JL14400

Regulatory Status:
Alternative:

SDCN; SYND3; N-Syndecan; Syndecan Proteoglycan 3

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.62-40ng/mL
Sensitivity:
0.22ng/mL
Specificity:
This kit recognizes Human SDC3 in samples. No significant cross-reactivity or interference between Human SDC3 and analogues was observed.
Sample Type:
Tissue homogenates and other biological fluids.
Assay Procedure:
Assay Procedure
Research Area:
Cancer
  • Human Syndecan 3 (SDC3) ELISA Kit
  • Human Syndecan 3 (SDC3) ELISA Kit
  • Human Syndecan 3 (SDC3) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| SDC3

Syndecan-3 is a protein that is encoded by the SDC3 gene.The protein encoded by this gene belongs to the syndecan proteoglycan family. It may play a role in the organization of cell shape by affecting the actin cytoskeleton, possibly by transferring signals from the cell surface in a sugar-dependent mechanism. Allelic variants of this gene have been associated with obesity.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 40 20 10 5 2.5 1.25 0.62 0
OD 2.66 1.97 1.36 0.83 0.51 0.32 0.2 0.08
Corrected OD 2.58 1.89 1.28 0.75 0.43 0.24 0.12 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human SDC3 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Tissue Homogenates(n=8) 97-108 103





 

| Linearity

Samples were spiked with high concentrations of Human SDC3 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Tissue Homogenates(n=4)
1 : 2 Range (%) 90-110
Average (%) 96
1 : 4 Range (%) 105-115
Average (%) 108







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
360 / 360
96T
1
460 / 460