Product Name:
Human Syntenin 2 (ST2) ELISA Kit
Cat.#:
JL15409
Regulatory Status:
Alternative:
SDCBP2; SITAC18; Syndecan Binding Protein 2
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.78-50ng/mL
Sensitivity:
0.37ng/mL
Specificity:
This kit recognizes Human ST2 in samples. No significant cross-reactivity or interference between Human ST2 and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates and other biological fluids
Assay Procedure:

Research Area:
Cancer
Product Datasheets
| ST2
Syntenin-2 is a protein that is encoded by the SDCBP2 gene.The protein encoded by this gene contains two class II PDZ domains. PDZ domains facilitate protein-protein interactions by binding to the cytoplasmic C-terminus of transmembrane proteins, and PDZ-containing proteins mediate cell signaling and the organization of protein complexes. The encoded protein binds to phosphatidylinositol 4, 5-bisphosphate (PIP2) and plays a role in nuclear PIP2 organization and cell division. Alternatively spliced transcript variants encoding multiple isoforms have been observed for this gene.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (ng/mL) | 50 | 25 | 12.5 | 6.25 | 3.12 | 1.56 | 0.78 | 0 |
OD | 2.64 | 1.78 | 1.09 | 0.64 | 0.41 | 0.31 | 0.23 | 0.09 |
Corrected OD | 2.55 | 1.69 | 1 | 0.55 | 0.32 | 0.22 | 0.14 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human ST2 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 89-101 | 96 |
Plasma(n=8) | 92-105 | 102 |
Tissue Homogenates(n=8) | 96-108 | 102 |
| Linearity
Samples were spiked with high concentrations of Human ST2 and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | Tissue Homogenates(n=4) | ||
1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
Average (%) | 91 | 93 | 96 | |
1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
Average (%) | 94 | 98 | 109 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460